
Category: Products
Hotline
Tel: +86 133 1175 6197
WeChat: L13311756197
Email: postmaster@suoqi-cable.com
In chemical, machine tool processing, and other scenarios, cutting fluids, oil stains, and acidic or alkaline media continuously corrode cable sheaths, causing general PVC/rubber materials to age and crack quickly, significantly shortening their service life. To address this issue, Shanghai Suoqi has optimized its polyurethane cables both in materials and processes: the conductors are multi-stranded, finely twisted, oxygen-free bare copper wires; the insulation is made of special elastomer materials; the outer sheath is imported polyurethane PUR/TPU, which is oil-resistant, acid and alkali-resistant, UV-resistant, and aging-resistant. In actual applications, the products have been recognized by customers in the mechanical, steel, and automation sectors for their polyurethane, tensile strength, and PUR performance. Customization according to drawings and direct shipment from stock are supported. For details, please contact 13311756197.
Product Features
Application range of polyurethane cables: Used for control equipment, such as machine tools, flow and assembly lines, conveyor systems and production lines, machinery and equipment construction, conveyor technology (e.g., work platforms and transport systems), the automotive industry, handling and automation technology, iron, steel and chemical industries, (e.g., drills, angle grinders, and other electric tools), industrial paint shops, water treatment plants, steel, automotive, mining... Structure of polyurethane cables: 1. Conductor: multi-stranded superfine twisted oxygen-free copper wire, meeting CDE0295 CLASS 6 standard 2. Rated voltage: cross-section <0.5mm²: 300/300V; cross-section ≥0.5mm²: 300/500V 3. Insulation: special blended TPE insulation 4. Test voltage: 2000V 5. Fixed installation: 6×D 6. Mobile installation: for travel application scenarios
Industrial automation, machinery manufacturing, port terminals, and mining operations
Technical Parameters
Parameter item
Technical indicators
Mechanical properties
Cable insulation materials are generally not subjected to high mechanical stress. On the other hand, sheaths are used extensively. This is especially suitable for flexible control and connection cables, which are often pulled over sharp corners and rough surfaces. This can lead to protruding cuts when stretching cables during flexible use. Compressive stress caused by squeezing and impacts by tools and machines may also occur.
The outstanding chemical properties of polyurethane cables are
1. Has good resistance to mineral oils 2. Has good resistance to non-alcohol gasoline 3. Has good resistance when stored in water 4. Has good resistance to many solvents Chemical example: 1. After long-term exposure to humid and warm conditions, polyester-type polyurethane is at risk of microbial degradation.
Application range of polyurethane cables
Used for controlling equipment such as machine tools, flow and assembly lines, conveyor systems and production lines, machine and equipment construction, conveyor technology (such as work platforms and transport systems), automotive industry, processing and automation technology, iron, steel, and chemical industries (such as drill bits, angle grinders, and other power tools), industrial paint shops, water treatment plants, steel, automotive, mining...... Polyurethane cable structure: 1. Conductor: Multi-strand ultra-fine finely twisted oxygen-free copper wire, compliant with CDE0295CLASS 6 standard 2. Rated voltage: cross-sectional < 0.5mm 2: 300/300V cross-sectional ≥0.5mm 2: 300/500V 3. Insulation: special mixed TPE insulation 4. Test voltage: 2000V 5. Fixed installation: 6×D 6. Mobile installation: as long as the travel is required
Customized services
As a source manufacturer of special flexible cables, Shanghai cable companies can customize polyurethane cables according to drawings or working conditions, with stable delivery times and controllable quality. Welcome to call 13311756197 for solutions and quotations.
Frequently Asked Questions
Will polyurethane cables hydrolyze?
Ether-based PUR has excellent hydrolysis resistance, far superior to polyester-based types. Ether-based formulations should be specified for long-term humid environments.
What is the temperature resistance of polyurethane cables?
Conventional polyether PUR is suitable for temperatures from -40°C to 90°C, and can be higher in the short term. When selecting, consider ambient temperature and mobile status for confirmation.
Related product recommendations
Bending life of equipment for polyurethane cables
Tensile Design of Equipment Manufacturing for Polyurethane Cables
Metallurgical Steel Installation Specifications for Polyurethane Cables